LG 31HN713D: 31" 12MP Mammography Monitor
Authorized LG diagnostic imaging equipment supplier. The 31HN713D is purpose-built for one application, mammography. It is one of the few mammography displays that combines a 31 inch 3:2 aspect ratio panel with a 12 megapixel native resolution and a built-in front sensor for self-calibration. It solves three persistent problems. Viewing bilateral exams requires panning on smaller displays, external calibration creates scheduling and downtime burdens, and legacy 5 megapixel mammography monitors cannot display a full tomosynthesis reconstruction stack without significant resolution loss.
The core technology is a 31 inch IPS panel at 4200 by 2800, which is 12 megapixel, with a 3:2 aspect ratio that allows bilateral CC and MLO views at near-full resolution at the same time. A front sensor self-calibration system maintains DICOM Part 14 accuracy through LG PerfectLum software without external instruments. A brightness of 1080 cd/m² with a 1500 to 1 contrast ratio supports the review of full-field digital mammography and digital breast tomosynthesis. LG positions the 12 megapixel resolution specifically as a display for mammography.
Need pricing? Get a quote with lead times and volume discounts within one business day.
12MP 3:2 Panel, Front Sensor Calibration, and Mammography Workflow
Three things set the 31HN713D apart from a standard mammography monitor. The 31 inch 12 megapixel 3:2 panel reduces the need to pan or zoom when reviewing bilateral exams, the internal front sensor removes the external photometer dependency, and Focus View with down and wall lighting speeds reading room workflow. Full technical detail is in the expandable sections below.
Panel: 31 inch IPS, 4200 by 2800 12 megapixel, 3:2 aspect ratio
Brightness, typical: 1080 cd/m²
Contrast Ratio: 1500:1
Response Time: 5 ms in faster setting, 14 ms standard
Viewing Angle: 178° horizontal and 178° vertical
Surface Treatment: anti-glare, 3H hardness
DICOM: Part 14 compliant
Front Sensor Self-Calibration: an internal front sensor performs DICOM Part 14 calibration on a scheduled basis or on demand with no external photometer required
Hardware Calibration: supported through LG PerfectLum software for documented quality assurance records
12 Megapixel for Mammography: LG positions the 31HN713D as a 12 megapixel display for mammography, and the resolution supports review of full-field digital mammography and digital breast tomosynthesis
Multi-resolution Mode: accepts 12 megapixel at 4200 by 2800 and 6 megapixel input signals for backward compatibility with existing PACS configurations
Focus View: highlights a region of interest such as a suspicious mass or a calcification cluster while dimming the surrounding image area, without changing the PACS window and level settings
Pathology Mode: optimized color fidelity for breast pathology correlation alongside mammographic images
Down and Wall Lighting: integrated ambient illumination for reviewing reports and patient files in a darkened reading room
Reader Mode and Flicker Safe: reduce eye fatigue during long interpretation sessions
How the 31HN713D compares against a standard 5MP mammography monitor:
The 31HN713D is distinguished by its 31 inch 3:2 canvas, the largest in the LG mammography diagnostic monitor lineup, combined with a built-in front sensor for self-calibration. Breast imaging centers that replace 21 inch 5 megapixel displays can view all four standard mammographic views at near-full resolution without panning, which reduces reading time per case and supports a smoother quality assurance workflow.
Full Technical Specifications
Complete reference data for procurement, RFP submissions, biomedical review, and accreditation documentation. Breast imaging center directors, radiology department heads, and biomedical engineers rely on this specification set when they evaluate mammography monitors. Expand each category for full detail.
| Resolution | 12 megapixel, 4,200 × 2,800 |
| Panel Type | IPS |
| Screen Size | 31 inch, 3:2 aspect ratio |
| Brightness, typical | 1080 cd/m² |
| Contrast Ratio, typical | 1500:1 |
| Response Time | 5 ms in faster setting, 14 ms standard |
| Viewing Angle | 178° horizontal and 178° vertical |
| Surface Treatment | Anti-glare, 3H hardness |
| DICOM | Part 14 compliant |
| Calibration | Internal front sensor self-calibration with LG PerfectLum hardware calibration |
| Weight, with stand | 14.0 kg, which is 30.9 lbs |
| Stand, Height Adjust | 110 mm |
| Stand, Tilt | Negative 5 to positive 15 degrees |
| Stand, Swivel | Plus or minus 15 degrees |
| VESA Wall Mount | 100 × 100 mm |
| Video Inputs | DisplayPort × 2 |
| USB Upstream | 1 |
| USB Downstream, hub | 3 |
| Multi-View | 2 picture by picture, side by side |
| AC Input | 100 to 240 V AC, 50 to 60 Hz |
| Power Consumption, maximum | 180 W |
| Power Consumption, DC off | Less than 1.5 W |
| Multi-Resolution Mode | 12 megapixel and 6 megapixel |
| PBP | 2 picture by picture |
| Pathology Mode | Yes |
| Focus View | Yes, dims surrounding areas to highlight the region of interest |
| Down and Wall Lighting | Yes, built-in ambient reading room illumination |
| Reader Mode and Flicker Safe | Yes |
| Hardware Calibration | Yes, LG PerfectLum with internal front sensor |
Clinical Applications
Deployed in breast imaging centers, hospital radiology departments, and outpatient mammography facilities where the 31 inch 12 megapixel canvas, front sensor self-calibration, and DICOM accuracy determine reading throughput and diagnostic confidence.
Display bilateral CC and MLO views at near-full 12 megapixel resolution on the 31 inch 3:2 canvas, which removes the panning and zooming required on standard 21 inch 5 megapixel mammography monitors.
Review tomosynthesis reconstruction stacks at 12 megapixel native resolution alongside full-field acquisitions. The 1080 cd/m2 brightness and 1500 to 1 contrast support slice by slice evaluation of dense breast tissue.
2 picture by picture displays a current mammography exam and a prior study from two sources side by side at the same time for direct comparison.
Focus View and built-in down and wall lighting reduce per-case reading time in high-throughput mammography screening programs where radiologist efficiency affects patient throughput.
Pathology Mode reproduces color accuracy comparable to microscope viewing for correlating biopsy slides alongside mammographic or tomosynthesis images from the PACS workstation.
Breast imaging centers upgrading from 21 inch 5 megapixel monitors gain a single 12 megapixel canvas for all four standard views and front sensor self-calibration for simpler quality assurance.
Mammography Reading Room Workflow
Self-calibration, reading efficiency features, and connectivity combine to support demanding mammography interpretation workflows under quality assurance programs. The expanded workflow detail is in the expandable sections below.
Front Sensor Self-Calibration: the built-in internal front sensor automatically performs DICOM Part 14 calibration on a scheduled basis or on demand through LG PerfectLum software, with no external photometer or manual intervention required, which removes radiologist downtime for quality assurance.
Hardware Calibration: hardware calibration through LG PerfectLum is supported for facilities that keep documented quality assurance records for ACR and MQSA programs.
DICOM Part 14: grayscale standard display function compliance for consistent mammographic image quality.
FDA 510(k) Class II: the monitor is FDA 510(k) Class II cleared, and LG positions the 12 megapixel resolution as a display for mammography. We recommend confirming the clearance indication and display quality assurance requirements for your accreditation.
Focus View: highlights a region of interest such as a suspicious lesion or a calcification cluster while dimming the surrounding areas of the mammographic image, which reduces visual distraction during detailed inspection without changing the PACS window and level settings.
Down and Wall Lighting: built-in ambient illumination supports reading reports and patient files in a darkened mammography reading room without straining the eyes or compromising the display calibration conditions.
Reader Mode and Flicker Safe: reduce eye fatigue during long mammography interpretation sessions.
Pathology Mode: optimized color rendering for breast pathology correlation alongside mammographic images.
Video Inputs: two DisplayPort inputs connect PACS workstations or mammography acquisition stations directly, with no adapters required for standard PACS configurations.
USB Hub: one upstream and three downstream USB ports for peripherals at the reading station.
2 Picture by Picture: display two full-resolution sources side by side, for comparing current and prior mammography exams or viewing full-field images alongside tomosynthesis reconstructions.
Stand Adjustments: swivel of plus or minus 15 degrees, tilt from negative 5 to positive 15 degrees, and a 110 millimeter height range for personalized ergonomic positioning during extended reading sessions.
VESA 100 by 100 mm: compatible with medical-grade monitor arms and wall mounts.
Regulatory Compliance and Quality Assurance
FDA 510(k) Class II cleared, positioned by LG as a 12 megapixel display for mammography, and certified to the EN 60601 medical electrical safety and EMC standards. Medical Outfitters is an ISO 13485:2016 certified supplier of diagnostic imaging equipment, so every 31HN713D ships through a documented and audited quality management system. Full compliance documentation is available in the expandable sections below.
FDA 510(k) Class II: the LG 31HN713D is FDA 510(k) Class II cleared, and LG positions the 12 megapixel resolution as a display for mammography that supports full-field digital mammography and digital breast tomosynthesis review. We recommend confirming the specific clearance indication and the MQSA display requirements for your facility.
CE marked: compliant with the European harmonized standards EN 60601-1 and EN 60601-1-2.
ISO 13485: Medical Outfitters is independently ISO 13485:2016 certified as a diagnostic imaging equipment supplier.
IEC 60601-1: meets the general safety requirements for medical electrical equipment.
IEC 60601-1-2: meets the electromagnetic compatibility requirements, so the monitor does not interfere with adjacent mammography acquisition equipment or PACS networking hardware.
cUL: certified to ANSI/AAMI ES 60601-1 and CSA C22.2 No. 60601-1 for the United States and Canada, and FCC Part 15 Class A.
RoHS: compliant with the Restriction of Hazardous Substances directive.
REACH: compliant with the European Union REACH chemical regulation.
WEEE: compliant with the European Union Waste Electrical and Electronic Equipment directive.
PACS & Calibration Compatibility Review
Share your PACS vendor, mammography acquisition systems, and quality assurance schedule. Our diagnostic imaging specialists confirm the 31HN713D DICOM configuration and LG PerfectLum calibration setup before your order ships.
Breast Imaging Center & RFP Support
Volume pricing, technical documentation, and logistics for breast imaging centers, hospital systems, and group purchasing teams. Full biomedical documentation is available for accreditation and equipment review committees.
Frequently Asked Questions
Quick answers to the most common purchase and technical questions about the LG 31HN713D mammography monitor. Tap any question to expand.
Yes. LG positions the 31HN713D as a 12 megapixel IPS display for mammography, and it is FDA 510(k) Class II cleared. Its 12 megapixel resolution and high brightness support the review of full-field digital mammography and digital breast tomosynthesis. We recommend confirming the specific FDA clearance indication and the MQSA display requirements for your facility, and our team can help you select the right monitor.
The built-in internal front sensor performs DICOM Part 14 calibration on a scheduled basis or on demand through LG PerfectLum software, with no external photometer required. This keeps the calibrated brightness consistent between cycles for reliable mammographic image quality, and hardware calibration with an external instrument is also supported for documented quality assurance records.
The 31 inch 3:2 panel lets radiologists display bilateral CC and MLO views at near-full 12 megapixel resolution at the same time, with much less panning and zooming than a smaller 5 megapixel display requires. This can reduce reading time per case and reduce eye strain during high-volume mammography reading sessions.
Focus View highlights a selected region of interest, such as a suspicious mass, a calcification cluster, or an architectural distortion, while dimming the surrounding image area. This draws attention to the area under review without changing the PACS window and level settings or losing the context of the surrounding breast tissue.
Yes. The 2 picture by picture feature displays two independent sources side by side at the same time, which suits comparing a current mammography exam against a prior study from a different PACS workstation, or viewing full-field digital mammography images alongside tomosynthesis reconstructions.
The 31HN713D supports 12 megapixel at 4200 by 2800 and 6 megapixel input signals. The 12 megapixel native resolution is used for full-resolution mammography and tomosynthesis review, and the 6 megapixel mode provides backward compatibility with existing PACS configurations without signal converters.
The 31HN713D is a 12 megapixel mammography display with FDA 510(k) Class II clearance, and its internal front sensor self-calibration supports the routine quality control documentation that MQSA and ACR programs expect. We recommend confirming the current display quality assurance requirements for your accreditation, and our team can assist with calibration setup and documentation.
Through Medical Outfitters Inc., an ISO 13485:2016 certified supplier based in Miami, FL. We supply factory-new units with calibration support, PACS integration assistance, and nationwide installation for breast imaging centers, hospitals, and radiology practices. Call (305) 885-4045 or request a quote online.
Compatible Equipment
Other LG diagnostic monitors from Medical Outfitters for breast imaging and multimodality radiology reading rooms.
LG 32HQ713D IPS Black Diagnostic Monitor
31.5" 8MP IPS Black · 1,000 cd/m² · internal front sensor · 2,000:1 · general radiology and mammography review
View Product
LG 32HL512D Nano IPS Diagnostic Monitor
31.5" 8MP Nano IPS · 450 cd/m² · DCI-P3 98% · HDMI and dual DP · multimodality color reading
View Product
LG 32HR734S-W Mini-LED Surgical Monitor
31.5" 4K Mini-LED · 2,000 cd/m² peak · IP45 · Clone Screen · for breast biopsy and surgical suites
View ProductRequest a Quote Today