Request a QUOTE!
Better systems, better service, and better healthcare are at your reach.
Overview
The Siemens Somatom Emotion 16 is incredibly compact and needs only 18 square meters of floor space. The Emotion 16 provides high quality images with minimal life-cycle cost. In addition, you will also have access to a wide range of clinical applications.
The Emotion 16 has been designed with a 70 cm aperture, a 50 cm scan field and a patient table that can hold patients up to 440 pounds. The Emotion 16 offers on-the-fly reconstruction of up to 16 images per second. A powerful and cost-effective scanner, the Emotion 16 will allow your clinic to perform routine exams as well as detailed and high resolution exams.
These units are to be sold installed as turn-key projects.
- 16-slice acquisition
- A wide range of clinical applications
- Fast and efficient with 0.6 second rotation time
- Multislice UFC detector
- 0.75 or 1.5mm slices per rotation in less than 20 seconds
- Small diagnostic detail for acquisition
- 105-millisecond temporal resolution for a clear depiction of blood vessels
- Scan any anatomy with a single breath hold
- Pathology can be seen from any perspective
- Low patient dose
Clinical Applications: Abdominal, Adult Cardiac, Functional Imaging, Pediatrics, Pelvis, Spinal, Thoracic
CT Technology
- syngo LungCARE CT with NEX (Nodule Enhanced Viewing)
- syngo Colonography with PEV (Polyp Enhanced Viewing)
Gantry
- Gantry Generation: 3rd
- Slipring: Low voltage
- Aperture: 70 cm
- FOV: 50 cm (standard), 70 cm (optional)
- Tilt range: ±30 degrees
- Type of positioning lights: Laser
- Accuracy of positioning lights: ±1 mm
- Focus-detector distance: 940 mm
Patient Couch/ Table
- Couch top material: Carbon fiber
- Couch top length and width: 222 x 43 cm
- Horizontal movement range: 153 cm
- Horizontal movement speeds: 1-100 mm/sec
- Accuracy/reproducibility of table positioning: ±0.25 mm (Horizontal movement)
- Scannable horizontal range without table top extension: 153 cm
- Scannable horizontal range with tabletop extension(s): 153 cm
- Vertical movement range out of gantry: 45-83 cm
- Vertical movement range in gantry: 64-83 cm
- Minimum couch top height outside gantry: 45 cm (Vertical movement)
- Maximum weight allowed on couch: 200 kg (440 lbs)
- Maximum weight on couch which still achieves stated performance specifications: 200 kg
- Type/Make: Siemens Dura 422MV Siemens Straton
- Focal spot size(s) quoted to (X-RAY TUBE): 0.5 mm x 0.8 mm
- IEC 336/93 standard (X-RAY TUBE) 0.7 x 0.8
- Settings at which focal spot change automatically; small changes
- kW = kV x mA / 1000: up to 28 kW ; large up to 45 kW
- Total filtration (inherent + beam shaping filter) at central axis (mm Al equivalent) (X-RAY TUBE) 6.3 (140kV)
- Anode heat capacity (MHU): 5
- Maximum anode cooling rate (kHU/min): 810
- Method of cooling (X-RAY TUBE) Oil to air
- Guaranteed tube life: 200,000 scan seconds
- Detector type: Solid state (Ultra Fast Ceramic)
- Maximum number of simultaneously acquired data sets (no. of slices): 16
- Number of detectors per row (Maximum anode cooling rate): 736 (1472 channels)
- Number of elements along z-axis (Maximum anode cooling rate): 24
- Effective length of each element at isocentre: 16 x 0.6 mm, 8 x 1.2 mm
- Total effective length of detector array at isocentre: 19.2 mm
- Option for more slices / rotation (Maximum anode cooling rate): Yes
- X-ray generator: VAC Power Needed
- Type: High frequency
- Location: Rotation assembly (Composition)
- Power rating – kV settings available (Maximum weight allowed on the couch): 50, 80, 110, 130 kW
- mA range and step size (Weight-bearing properties) 20-345(1mA steps)
- Maximum mA allowed for each kV (Weight bearing properties) 80 kV: 345 mA
- Monitor/ Screen Size: 19 inches
- Number of monitors at the console (functions of each if > 1) (Image monitor) Up to 6 (shared database)
- Image area matrix dimensions: 1024 x 1024
- Usual range of CT number displayed (HU) (Image monitor) (-10,240 to 30,710 if metal implants)
- The accuracy of distance measurements in x-y plane depends on pixel size (mm)
- Weighted CTDI (CTDIw or CTDIvol) displayed on console
- Dose Length Product (DLP) displayed on console (Dose information)
- Geometric Efficiency displayed on the console when 70% for all collimations
- Control methods: Mouse, keyboard