Fujifilm Lisendo 880: Cardiovascular Ultrasound System
Authorized Fujifilm ultrasound equipment supplier. The Fujifilm Lisendo 880, also branded the Lisendo 880LE, is a dedicated cardiovascular ultrasound system built to redefine cardiac imaging. Fujifilm designed it to achieve high reliability for the diagnosis and treatment of cardiac diseases, with accurate visualization of the heartbeat and blood flow. It is a mobile, cart based console with an ergonomic design that helps cardiology departments move hemodynamic evaluation to a new level.
The Lisendo 880 is supported by three innovations, Pure Image, Your Application, and Seamless Workflow. Pure Symphonic Architecture delivers premium cardiac image quality, while a deep set of applications including Vector Flow Mapping, LV eFLOW, dual gate Doppler with R-R Navigation, Global Longitudinal Strain, 2D Tissue Tracking, and Cardiac 3D extends diagnostic confidence. HemoDynamic Structural Intelligence automates ejection fraction, fractional area change, and chamber volume measurement, and a 22 inch OLED monitor with four active and two parking transducer ports keeps each exam fast and comfortable.
Need pricing? Get a quote with lead times and volume discounts within one business day.
Pure Symphonic Architecture and Advanced Cardiac Applications
The Lisendo 880 is built for cardiology from the ground up. A premium imaging platform drives a deep set of cardiac and vascular applications, supported by automated measurement that speeds the path to a confident read. Full technical detail is in the expandable sections below.
Vector Flow Mapping (VFM): visualizes the direction and speed of intracardiac blood flow to support evaluation of cardiac hemodynamics
LV eFLOW: high resolution low velocity blood flow imaging that improves endocardial border definition
iDGD, Dual Gate Doppler with R-R Navigation: observes Doppler waveforms from two sample sites at the same time with automatic R-R interval measurement
Global Longitudinal Strain (GLS): quantifies left ventricular strain to support early detection of cardiac dysfunction
i2DTT, 2D Tissue Tracking: qualifies the strain rate of the ventricles for detailed functional assessment
Cardiac 3D and 4D: detailed three dimensional and four dimensional views of the heart with dedicated analysis
HemoDynamic Analytics: the HDAnalytics package supports heart failure diagnosis through detailed hemodynamic measurement
Pure Symphonic Architecture: a premium imaging platform engineered for the image quality cardiac diagnosis demands
2D TTE Transducer: a transthoracic transducer optimized for cardiology exams
eFocusing and Active Back-end: refine the signal for sharper detail and cleaner images
HI REZ: image enhancement that reduces noise and improves clarity
Vascular Suite: iVascular, Auto IMT, Linear CW, and eTRACKING with Wave Intensity support carotid and peripheral vascular studies
Transducer Ports: four active and two parking ports keep several transducers connected and ready without unplugging and replugging
How the Lisendo 880 compares against a general-purpose ultrasound system:
The Lisendo 880 attains the next level in operability through HemoDynamic Structural Intelligence. The automated cardiac function measurement package performs Automated ED-ES Detection and calculates Fractional Area Change, Left Ventricular Volume and Ejection Fraction, Right Atrial Volume, and Left Atrial Volume. Streamlined measurement operation, an intuitive operating console, and an advanced cardiac report reduce the number of manual button operations during an exam. Technologists can save protocols and imaging conditions, customize buttons, and use programmable presets, so routine cardiology exams move quickly and consistently.
Full Technical Specifications
Complete reference data for capital procurement, RFP submissions, and biomedical review. Cardiology directors, sonographers, and biomedical engineers rely on this specification set when they evaluate a dedicated cardiovascular ultrasound system. Expand each category for full detail.
| Vector Flow Mapping | VFM visualization of intracardiac blood flow direction and speed |
| LV eFLOW | Low velocity blood flow imaging with improved endocardial border definition |
| Dual Gate Doppler | iDGD with R-R Navigation for simultaneous Doppler from two sample sites |
| Global Longitudinal Strain | GLS quantification of left ventricular strain |
| 2D Tissue Tracking | i2DTT assessment of ventricular strain rate |
| Cardiac 3D and 4D | Three and four dimensional cardiac imaging and analysis |
| HemoDynamic Analytics | HDAnalytics package for heart failure diagnosis |
| iVascular | Dedicated vascular imaging application |
| eTRACKING | Vessel wall tracking for elasticity assessment |
| Wave Intensity | Wave Intensity (WI) analysis of cardiovascular interaction |
| Auto IMT | Automated intima media thickness measurement |
| Linear CW | Continuous wave Doppler on linear transducers |
| Architecture | Pure Symphonic Architecture premium cardiac imaging platform |
| Transducer | 2D TTE transthoracic transducer optimized for cardiology |
| Signal Processing | eFocusing and Active Back-end for sharper detail |
| Image Enhancement | HI REZ noise reduction and clarity enhancement |
| Automated ED-ES Detection | Automatic detection of end diastole and end systole |
| Fractional Area Change | Automated FAC measurement |
| LV Volume and EF | Automated left ventricular volume and ejection fraction |
| Atrial Volumes | Automated right atrial and left atrial volume measurement |
| Reporting | Advanced cardiac report with streamlined measurement operation |
| Monitor | 22 inch OLED monitor with image enhancing technology |
| Monitor Arm | Fully adjustable arm that tilts, swivels, and extends |
| Control Panel | Moveable control panel with adjustable height, tilt, and swivel |
| Transducer Ports | Four active and two parking transducer ports |
| Presets | Programmable presets and customizable buttons for saved protocols |
Clinical Applications
Deployed across cardiology and vascular programs where dedicated cardiac tools, automated measurement, and premium image quality decide how confidently a cardiologist can read the study.
A 2D TTE transducer and Pure Symphonic Architecture deliver the cardiac image quality needed for routine and detailed transthoracic echocardiography.
The HemoDynamic Analytics package, Global Longitudinal Strain, and automated ejection fraction support the assessment and follow up of heart failure.
Vector Flow Mapping, LV eFLOW, and dual gate Doppler with R-R Navigation move hemodynamic evaluation to a more detailed level.
GLS and 2D Tissue Tracking quantify ventricular strain to support early detection of cardiac dysfunction before ejection fraction falls.
iVascular, Auto IMT, eTRACKING, and Wave Intensity support carotid and peripheral vascular assessment alongside cardiac work.
HDSI automation, programmable presets, and an advanced cardiac report keep a busy cardiology service efficient and consistent.
From Transducer Setup to the Cardiac Report
A cardiology workflow built to move from patient setup to a confident read. Ready transducers, premium acquisition, and automated measurement keep each echo exam efficient. Expanded workflow details are in the expandable sections below.
Four active and two parking transducer ports keep several probes connected and ready, so technologists select the right transducer without unplugging and replugging. The 22 inch OLED monitor on a fully adjustable arm and a moveable control panel let staff position the console comfortably for each cardiac exam.
Pure Symphonic Architecture and the 2D TTE transducer capture premium cardiac images. Vector Flow Mapping and LV eFLOW visualize blood flow, while dual gate Doppler with R-R Navigation observes Doppler waveforms from two sites at once for detailed hemodynamic assessment.
HemoDynamic Structural Intelligence performs Automated ED-ES Detection and measures fractional area change, left ventricular volume and ejection fraction, and atrial volumes. Streamlined measurement operation reduces manual button presses and keeps exams short.
An advanced cardiac report compiles measurements and strain analysis for the reading cardiologist. Finished studies and reports route to PACS through DICOM for archiving, review, and comparison with prior exams.
Regulatory Compliance and Safety
FDA cleared as a diagnostic ultrasound system, manufactured by FUJIFILM Healthcare Corporation. Medical Outfitters is an ISO 13485:2016 certified supplier of ultrasound equipment, so every Lisendo 880 ships through a documented and audited quality management system. Full compliance documentation is available in the expandable sections below.
FDA Cleared: the Fujifilm Lisendo 880 is FDA cleared as a diagnostic ultrasound system, suitable for cardiology departments, echocardiography labs, and vascular imaging programs.
ISO 13485: Medical Outfitters Inc. is independently ISO 13485:2016 certified as an ultrasound equipment supplier, so every system ships through a fully audited quality management system.
Electrical Safety: the Lisendo 880 meets IEC 60601 electrical safety standards for diagnostic ultrasound systems.
Acoustic Output: acoustic output display and controls support adherence to the ALARA principle during cardiac and vascular exams.
DICOM and PACS: studies and reports route to PACS through DICOM for archiving and review.
RoHS: Restriction of Hazardous Substances compliant.
REACH: EU REACH chemical regulation compliant.
Applications & Transducer Review
Tell us your cardiology and vascular case mix and your preferred transducers. Our team confirms the right configuration, coordinates applications training, and arranges installation before shipment.
Capital Equipment & RFP Support
Volume pricing, technical documentation, and logistics for cardiovascular ultrasound deployments. We support cardiology directors, biomedical engineers, and purchasing departments evaluating echocardiography systems. Contact us for RFP packages.
Frequently Asked Questions
Quick answers to the most common purchase and clinical questions about the Fujifilm Lisendo 880 cardiovascular ultrasound system. Tap any question to expand.
The Fujifilm Lisendo 880, also known as the Lisendo 880LE, is a dedicated cardiovascular ultrasound system built for echocardiography and vascular imaging. It pairs Pure Symphonic Architecture image quality with advanced cardiac applications such as Vector Flow Mapping, LV eFLOW, dual gate Doppler, and strain analysis, and it automates cardiac function measurement through HemoDynamic Structural Intelligence.
The Lisendo 880 supports Vector Flow Mapping for intracardiac hemodynamics, LV eFLOW for low velocity blood flow and endocardial border definition, dual gate Doppler with R-R Navigation, Global Longitudinal Strain, 2D Tissue Tracking for strain rate, and Cardiac 3D and 4D. The HemoDynamic Analytics package supports heart failure diagnosis.
The Lisendo 880 is a dedicated cardiovascular and echocardiography console with cardiac specific tools such as Vector Flow Mapping, dual gate Doppler, and automated ejection fraction. The Fujifilm Arietta 850 is a premium general imaging system for broad clinical use, and the Sonosite M-Turbo, Edge II, and ZX are portable point of care systems. Choose the Lisendo 880 when cardiology is the primary focus.
Vector Flow Mapping, written as VFM, visualizes the direction and speed of blood flow inside the heart to support evaluation of cardiac hemodynamics. It helps clinicians move hemodynamic evaluation to a more detailed level than color Doppler alone.
HemoDynamic Structural Intelligence, written as HDSI, is an automated cardiac function measurement package. It performs automated end diastole and end systole detection and measures fractional area change, left ventricular volume and ejection fraction, and right and left atrial volumes, which reduces manual steps and speeds reporting.
The Lisendo 880 features a 22 inch OLED monitor on a fully adjustable arm, a moveable control panel with adjustable height, and four active plus two parking transducer ports. The active ports keep several transducers connected and ready, so technologists do not need to unplug and replug probes between exams.
Yes. The Fujifilm Lisendo 880 is FDA cleared as a diagnostic ultrasound system. Medical Outfitters Inc. is ISO 13485:2016 certified as the supplying distributor, so every system ships through an audited quality management system.
Through Medical Outfitters Inc., ISO 13485:2016 certified, Miami, FL. We supply factory new systems with nationwide installation and applications support. Call (305) 885-4045 or request a quote online.
Compatible Equipment
Other Fujifilm ultrasound systems to consider alongside the Lisendo 880, from the premium Arietta 850 general imaging platform to the Sonosite Edge II and M-Turbo portable point of care systems for bedside cardiac and vascular work.
Fujifilm Arietta 850 DeepInsight
Premium ultrasound · general imaging · DeepInsight · doppler and strain
View Product
Fujifilm Sonosite Edge II
Portable ultrasound · point of care · rugged · bedside imaging
View Product
Request a Quote Today
Get in touch with Medical Outfitters today to request your personalized quote and outfit your facility with confidence.