Fujifilm Persona RF PREMIUM Plus: Digital Radiography and Fluoroscopy Table
Authorized Fujifilm radiography and fluoroscopy equipment supplier. The Persona RF PREMIUM Plus introduces next generation digital RF technology with a highly flexible system design. It is engineered for true multi purpose workflow and positioning flexibility for interventional and routine radiographic examinations. The system fits tight spaces without sacrificing versatility and accommodates all types of fluoroscopy and general radiography exams, including chest and long length exams, without the need for an overhead tube and chest stand.
An 80 kW generator provides ample power for even the most demanding exams, while the integrated 17×17 inch IGZO detector delivers 140 micron resolution at up to 30 frames per second for smooth, high definition fluoroscopy. A single operator console with Anatomic Programming drives the table, the table tilts plus or minus 90 degrees with 94 inches of longitudinal coverage and a 71 inch source to image distance, and a 584 pound carbon fiber table with a low 19 inch height serves bariatric and stretcher bound patients with ease.
Need pricing? Get a quote with lead times and configuration options within one business day.
Integrated RF Design, IGZO Detector, and Single-Console Workflow
The Persona RF PREMIUM Plus introduces a smartly designed approach with an extensive range of motion and ease of use that sets it apart from traditional radiographic fluoroscopy systems. An integrated design, a dynamic IGZO detector, and a single console drive the most demanding exams. Full technical detail is in the expandable sections below.
Integrated RF Design: combines fluoroscopy and radiography in a single compact system, with no need for a separate chest stand or overhead tube crane, which maximizes space utilization while delivering full clinical capabilities
Reduced Footprint: the generator and workstation cabinets integrate into the back of the table, which reduces the footprint, simplifies installation, and fits rooms as small as 180 square feet
Single Operator Console: a unified image acquisition and quality assurance workstation processes continuous or pulsed fluoroscopy, radiographic imaging, and image stitching from one interface
Anatomic Programming: APR integration interfaces with joystick table controls for positioning speed and confidence, and presets automatically adjust technique based on patient age and anatomy
Go to Position: automatic dose free positioning moves the system to the correct orientation for chest, abdomen, or extremity exams without any exposure, which reduces setup time
Single Generator: one generator powers both the RF table and an optional overhead tube crane, which eliminates the cost of a second generator
17×17 Inch IGZO Detector: the 140 micron high resolution Indium Gallium Zinc Oxide detector provides maximum field of view with exceptional image detail and dose performance
High Speed Fluoroscopy: up to 30 frames per second enables smooth real time imaging for barium studies and interventional procedures, with a DQE of 79 percent at 0 line pairs per millimeter and 56 percent at 1 line pair per millimeter
Imaging Modes: radiography, fluoroscopy at 15, 7.5, 3, and 1 frames per second plus continuous, and linear tomography are standard
Clinical Options: image stitching for up to four views, digital subtraction angiography with roadmap, and urology isocentric rotation extend the clinical range
FDR D-EVO III Integration: optional glass free, lightweight detectors under 4 pounds with a HydroAG antibacterial coating, IPX6 fluid protection, and ISS technology for sharper images at a lower dose
Dose Efficiency: ISS positions capture circuitry at the irradiation side to suppress scatter and attenuation, optimized to the ALARA principle for pediatric and repeat exams
How the Persona RF PREMIUM Plus compares against a conventional RF room:
The Persona RF PREMIUM Plus pairs robust construction with intuitive controls. A carbon fiber tabletop measuring 94.5 by 33.5 inches supports up to 584 pounds of patient weight without movement restrictions and up to 716 pounds stationary, with an excellent strength to weight ratio and low attenuation. A low table height of 19 inches aids patient transfer from wheelchairs and stretchers, and superior positioning lets the tube column reach stretcher bound patients without a ceiling suspended overhead tube crane. With no separate chest stand or additional generator, the system fits into rooms as small as 180 square feet on standard electrical service.
Full Technical Specifications
Complete reference data for capital procurement, RFP submissions, and facility planning. Radiology directors, purchasing teams, and biomedical engineers rely on this specification set when they plan a digital radiography and fluoroscopy room. Expand each category for full detail.
| Tabletop | 94.5 by 33.5 inches, carbon fiber |
| Table Height | 19 to 51 inches |
| Tilting Angle | Plus or minus 90 degrees, tilt speed 6 degrees per second, maximum 10 degrees per second |
| Longitudinal Coverage | 94.5 inches, longitudinal speed 4.7 inches per second |
| Source to Image Distance | 43 to 71 inches (110 to 180 cm) |
| Tube Column | 71 inch movement with plus or minus 180 degree rotation |
| Generator | 80 kW high frequency |
| kV Range | 40 to 150 kV in 1 kV steps |
| Fluoroscopy | 0.5 to 10 mA continuous, 10 to 20 mA pulsed |
| Radiography | 10 to 1000 mA |
| X-ray Tube | Rotating anode, dual focus 0.6 and 1.0 |
| Anode Heat Capacity | 450 kJ (600 kHU) or 580 kJ (800 kHU) option, with a second tube output for an overhead tube crane |
| Technology | Indium Gallium Zinc Oxide TFT |
| Pixel Pitch | 140 micron |
| Spatial Resolution | 3.5 line pairs per millimeter |
| Grayscale | 16 bit radiography and fluoroscopy |
| X-ray Sensitive Array | 17×17 inch (43×43 cm) |
| DQE | 79 percent at 0 line pairs per millimeter, 56 percent at 1 line pair per millimeter |
| Max Frame Rate | 30 frames per second fluoroscopy |
| Standard Modes | Radiography, fluoroscopy at 15, 7.5, 3, and 1 fps plus continuous, linear tomography |
| Image Stitching | Up to 4 views, upright or supine |
| Digital Subtraction Angiography | DSA with roadmap for vascular and interventional procedures |
| Urology | Isocentric rotation for urologic procedures |
| Console | All modes accessible from a single console |
| Patient Weight | Up to 584 pounds without movement restrictions, 716 pounds stationary |
| With D-EVO III | Up to 683 pounds patient weight |
| Low Table Height | 19 inches for easy patient transfer |
| Room Size | Fits rooms as small as 180 square feet |
| Electrical | Standard 208 to 240 V, no special cooling required |
Clinical Applications
Deployed across radiography and fluoroscopy programs where room flexibility, a wide range of exams, and patient access decide how much one table can do, from outpatient clinics to busy hospital RF suites.
A full 71 inch source to image distance supports unencumbered chest and general radiography without a ceiling suspended tube, which suits space limited rooms.
The 17×17 IGZO detector at up to 30 frames per second delivers smooth real time fluoroscopy for barium and gastrointestinal studies.
Urology isocentric rotation supports urologic fluoroscopy and contrast studies on the same table.
Automated long length imaging with up to four view stitching captures full spine and full leg studies upright or supine.
A 584 pound table, a low 19 inch height, and a tube column that rotates plus or minus 180 degrees reach stretcher bound and bariatric patients.
An integrated generator and no separate chest stand let the system fit rooms as small as 180 square feet in outpatient and orthopedic centers.
Positioning, Imaging, and PACS Integration
A radiography and fluoroscopy workflow built around one table and one console. Easy positioning, automated technique, advanced exams, and full DICOM integration keep the room moving. Expanded workflow details are in the expandable sections below.
A low 19 inch table height aids transfer from wheelchairs and stretchers, and Go to Position dose free positioning moves the system to the correct orientation for chest, abdomen, or extremity exams without any exposure. A joystick, tableside keypad, handheld remote, and optional 7 way foot pedal let each operator pilot the table, with 3D anti collision and a deadman switch for safety.
Anatomic Programming presets automatically adjust technique based on patient age and anatomy, from pediatric to bariatric, and powerful image processing maintains consistent image quality. The single console switches instantly between fluoroscopy and radiography for an uninterrupted workflow.
The IGZO detector captures smooth fluoroscopy at up to 30 frames per second for barium and interventional studies. Image stitching produces up to four view long length images, digital subtraction angiography adds mask subtraction and roadmap, and urology isocentric rotation supports urologic procedures.
Full DICOM support includes Modality Worklist, Store, Print, MPPS, RDSR structured dose report, and Storage Commitment for smooth interoperability with PACS, RIS, and HIS. Dose reports are automatically archived for regulatory compliance, and ISS technology keeps the dose low under the ALARA principle.
Regulatory Compliance and Safety
FDA cleared as a radiographic and fluoroscopic X-ray system, manufactured by FUJIFILM Healthcare Americas Corporation. Medical Outfitters is an ISO 13485:2016 certified supplier of digital radiography equipment, so every Persona RF PREMIUM Plus ships through a documented and audited quality management system. Full compliance documentation is available in the expandable sections below.
FDA Cleared: the Fujifilm Persona RF PREMIUM Plus is FDA cleared as a radiographic and fluoroscopic X-ray system, suitable for hospital radiology departments and outpatient imaging centers.
ISO 13485: Medical Outfitters Inc. is independently ISO 13485:2016 certified as a digital radiography equipment supplier, so every system ships through a fully audited quality management system.
ISS Dose Efficiency: ISS technology suppresses scatter and attenuation to produce sharper images at a lower dose, optimized to the ALARA principle for pediatric and repeat exams.
Dose Reporting: RDSR structured dose reports are automatically archived for regulatory compliance.
DICOM and PACS: DICOM Modality Worklist, Store, Print, MPPS, RDSR, and Storage Commitment for PACS, RIS, and HIS interoperability.
Hygiene: optional FDR D-EVO III detectors carry a HydroAG antibacterial coating and IPX6 fluid protection.
Environmental: RoHS and EU REACH compliant.
Room Planning & Configuration Review
Provide your room dimensions and exam mix. Our imaging specialists confirm fit, including detector options, an overhead tube crane, and a wall stand, and coordinate site planning, installation, and training.
Capital Equipment & RFP Support
Volume pricing, technical documentation, and logistics for radiography and fluoroscopy deployments. We support radiology directors, biomedical engineers, and purchasing departments evaluating RF rooms. Contact us for RFP packages.
Frequently Asked Questions
Quick answers to the most common purchase and technical questions about the Fujifilm Persona RF PREMIUM Plus digital radiography and fluoroscopy table. Tap any question to expand.
The Fujifilm Persona RF PREMIUM Plus is a next generation digital radiography and fluoroscopy table, often called an RF table. It is engineered for true multi purpose workflow and positioning flexibility for interventional and routine radiographic examinations, and it accommodates all types of fluoroscopy and general radiography exams, including chest and long length exams, in a single compact system.
No. The integrated design combines fluoroscopy and radiography in one system, so it does not require a separate chest stand or overhead tube crane. The tube column extends horizontally and rotates plus or minus 180 degrees to reach patients on gurneys or in wheelchairs. An overhead tube crane and a tilting vertical wall stand are available as options for facilities that want them.
It uses a dynamic 17×17 inch IGZO detector, which is an Indium Gallium Zinc Oxide TFT flat panel with a 140 micron pixel pitch and a 43 by 43 centimeter array. It provides a spatial resolution of 3.5 line pairs per millimeter, 16 bit grayscale, a DQE of 79 percent at 0 line pairs per millimeter and 56 percent at 1 line pair per millimeter, and up to 30 frames per second fluoroscopy for smooth real time imaging.
The carbon fiber tabletop measures 94.5 by 33.5 inches with a height range of 19 to 51 inches. The table tilts plus or minus 90 degrees, offers 94.5 inches of longitudinal coverage, and supports a source to image distance from 43 to 71 inches. The tube column moves 71 inches and rotates plus or minus 180 degrees for flexible positioning.
The system supports radiography, fluoroscopy at 15, 7.5, 3, and 1 frames per second plus continuous, and linear tomography as standard. Options include image stitching for up to four views upright or supine, digital subtraction angiography with roadmap for vascular and interventional procedures, and urology isocentric rotation. All modes are accessible from a single console.
The table supports up to 584 pounds of patient weight without movement restrictions and up to 716 pounds stationary, and up to 683 pounds with the FDR D-EVO III detector. A low table height of 19 inches facilitates patient transfer from wheelchairs and stretchers, which makes it well suited to bariatric and mobility limited patients.
Yes. The Fujifilm Persona RF PREMIUM Plus is FDA cleared as a radiographic and fluoroscopic X-ray system. Medical Outfitters Inc. is ISO 13485:2016 certified as the supplying distributor, so every system ships through an audited quality management system, with full DICOM and dose reporting support.
Through Medical Outfitters Inc., ISO 13485:2016 certified, Miami, FL. We provide sales, site planning, installation, and training, and our specialists help configure detector options, an overhead tube crane, a wall stand, and software packages. Call (305) 885-4045 or request a quote online.
Compatible Equipment
Other Fujifilm digital radiography systems and detectors that work alongside the Persona RF PREMIUM Plus, from the FDR Clinica X and FDR Smart X X-ray rooms to the FDR D-EVO III detector it integrates with.
Fujifilm FDR Clinica X
Scalable DR suite · OTC and FS · FDX Console PLUS · D-EVO detectors
View Product
Fujifilm FDR D-EVO III
Flat panel detector · glass free · HydroAG · integrates with the RF table
View ProductRequest a Quote Today