Skip to content

IV Contrast for CT: What It Is, How It Is Given and the Injector Behind It

Published on November 27, 2026
Technologist with a tablet beside a patient lying with arms raised on the table of a Siemens SOMATOM X.cite CT scanner, with a dual-syringe contrast power injector on a wheeled stand connected to the patient's IV line, photo courtesy of Siemens Healthineers, with the Medical Outfitters watermark
Quick answer: IV contrast for CT is an iodine-based liquid injected into a vein, usually in the arm, so that blood vessels and organs stand out on the images. RadiologyInfo, the patient site of the RSNA and the ACR, says it can bring a warm, flushed feeling and a metallic taste that last a few minutes. A power injector delivers it at a set rate.

IV contrast for CT is the part of a CT scan that patients ask about most and that buyers of a scanner think about least. For the patient it is an IV line in the arm, a machine on a stand beside the table and a brief wave of warmth. For the facility it is a second piece of equipment, the power injector, with its own controls, its own consumables and its own place in the room, and it is the reason scanner speed matters on anything more demanding than a plain head scan. This guide explains what the iodine-based contrast does on the image, how it is given through the IV line and the injector, what patients report feeling as the published patient sources describe it, how the scan is timed to the phases of enhancement, the screening questions an imaging center asks beforehand, and the equipment side: single head, dual head and syringeless injectors and what they ask of the scanner. It names sources for every figure and recommends no brand.

Medical Outfitters sells CT scanners new from Fujifilm and refurbished from GE, Siemens, Philips, Canon and Hitachi through its MO Select line, and installs and services them across the United States, Puerto Rico and the Caribbean. This article is written for the administrators, radiology managers and clinicians who plan a CT room, and for patients who want to know what the injection involves. It is not medical advice. Whether a scan needs contrast, and how a patient prepares for it, are decisions for the patient’s own doctor and imaging center, and their instructions come first.

  • What it is: an iodine-based contrast material that blocks X-rays, so the vessels and organs that hold it look brighter on the CT image, per RadiologyInfo.
  • How it is given: through a flexible plastic cannula in an arm vein, by a power injector at a set flow rate, as the ACR Manual on Contrast Media describes.
  • What patients feel: a warm flush and a metallic taste for a few minutes, per RadiologyInfo; MedlinePlus says the sensations usually pass within a few seconds.
  • Timing: one published review places the early arterial phase of the liver at 15 to 25 seconds after injection and the portal venous phase at 70 to 80 seconds.
  • The equipment: the injector is a separate FDA-regulated device with one syringe, two syringes or no syringes at all, and the scanner must be fast enough to catch each phase.
Definition

What IV Contrast for CT Is and What It Does on the Image

A CT scanner maps how strongly each point in the body stops X-rays. Bone stops a great deal and shows clearly. Soft tissues are harder to tell apart: the National Institute of Biomedical Imaging and Bioengineering (NIBIB) explains that soft tissues vary in their ability to stop X-rays and may be faint or difficult to see, which is why contrast agents were developed. For the circulatory system, NIBIB says, an intravenous contrast agent based on iodine is injected into the bloodstream to help illuminate blood vessels.

RadiologyInfo describes the mechanism in plain terms. Contrast materials, also called contrast agents or contrast media, are not dyes that permanently discolor internal organs. They are substances that temporarily change the way X-rays interact with the body. When an iodine-based material is present in a part of the body, it blocks or limits the ability of X-rays to pass through, so the blood vessels, organs and other tissue that temporarily contain it change their appearance on the CT image. The same page lists what intravenous iodine-based contrast is typically used to enhance: internal organs including the brain, heart, lungs, liver, kidneys and pancreas, the gastrointestinal tract, the arteries and veins of the body, and other tissue including muscle and bone. Afterward, RadiologyInfo says, the material is absorbed by the body or eliminated through urine or bowel movements.

The contrast agent CT departments inject today is not the product of a generation ago. The ACR Manual on Contrast Media, 2026 edition, notes that the older ionic high-osmolality agents are now rarely or never used for injection into blood vessels because of their greater adverse event profile, and that the low-osmolality nonionic agents in current use are associated with a very low incidence of acute adverse events. People search for this exam under many names, a CT scan with IV contrast, CT intravenous contrast, CT scan IV contrast, and they all mean the same thing: a CT taken while iodine is in the bloodstream. Which exams are done with it and which without is the subject of our guide to CT scans with contrast vs without; this article stays with the injection itself.

IV contrast for CT, from the IV line to the imageIV contrast for CT, from the IV line to the imageThe usual order, as the ACR Manual on Contrast Media and RadiologyInfo describe it1ScreeningPrior reactions, allergies, kidneyhistory and medicines2IV lineA flexible plastic cannula, usually inan arm vein3Line checkBackflow check and a saline test flush4InjectionThe power injector delivers a set volumeat a set rate5Timed scanThe scan starts when contrast reachesthe target6AfterwardLine out, usual activities, extra fluidsSources: ACR Manual on Contrast Media 2026; RadiologyInfo, Contrast Materials. Your center's steps apply.
Figure 1. The path of an IV contrast injection for CT. The injection is seconds long; the screening and the line check before it are where the care goes.
The IV Line

How IV Contrast Is Given: The IV Line

The contrast reaches the bloodstream through a small plastic tube placed in a vein before the scan. MedlinePlus, the National Library of Medicine’s patient encyclopedia, says contrast may be delivered through a vein in the hand or forearm, and RadiologyInfo’s page on CT angiography says the contrast material is injected through a small catheter placed in a vein of the arm.

The ACR Manual on Contrast Media sets out what the imaging team looks for in that line. Intravenous contrast should be given by power injector through a flexible plastic cannula, and metal needles should be avoided for power injection whenever possible. An antecubital vein, at the bend of the elbow, or a large forearm vein is the preferred site. The flow rate should suit the gauge of the catheter: the manual says a 20-gauge or larger catheter is preferable for flow rates of 3 milliliters per second or greater, although 22-gauge catheters may be able to tolerate rates up to 5 milliliters per second. If a hand or wrist vein has to be used, the manual advises reducing the flow rate if feasible, for example to 1 to 2 milliliters per second.

The line is checked before the contrast goes in. The ACR manual describes several maneuvers: the catheter can be checked for backflow of blood, and a saline test flush can be performed by hand or once the tubing is connected to the power injector. If the site is tender or infiltrated during those checks, the manual says another site should be sought. Subject to state law, the manual adds, a radiologist, a radiologic technologist or a nurse may administer contrast media.

Clinician checking the IV line at a patient's arm on the table of a Siemens SOMATOM X.cite CT scanner, with the contrast injector and a saline bag on the stand beside them, photo courtesy of Siemens Healthineers
The IV line comes first. The ACR Manual on Contrast Media describes checking the catheter and flushing it with saline before the power injector delivers the contrast. Photo courtesy of Siemens Healthineers.

Communication is part of the technique. The ACR manual requires a means of easy communication between the technologist and the patient before, during and after the injection, first face to face and then by intercom or television system once the technologist has left the room, and it says the patient should be told to report any change in sensation, including increasing pain or swelling at the injection site.

The Injector

The Power Injector: What It Is and What It Controls

Contrast for CT is rarely pushed by hand. The ACR Manual on Contrast Media states that bolus or power injection of IV contrast material is superior to drip infusion for enhancing normal and abnormal structures during body CT, and that with proper technique contrast can be safely administered by power injector in the vast majority of patients, even at high flow rates.

A power injector is a regulated medical device in its own right. The FDA classifies it as a Class II device under 21 CFR 870.1650, angiographic injector and syringe. One FDA 510(k) summary for a current CT injector, the Bayer MEDRAD Stellant FLEX (K192370, prepared in December 2019), describes the type well: a software-controlled power injection system made up of an injector head and mount, a base and a workstation, designed to let the user fill disposable syringes and perform an injection with a user-set volume, flow rate or duration. The figures in that summary show what the technologist is setting. They describe one cleared device and are given here as an example, not a recommendation.

FeatureWhat the FDA 510(k) summary K192370 lists
SyringesDual syringe system, 200 mL or 150 mL syringe size
Flow rate range0.1 to 10 mL per second
Programmable pressure limitA choice of settings from 50 psi to 325 psi
Protocol memory250 protocols of up to 6 phases each
Hold capability20 minutes maximum
Test injectYes
Simultaneous injectionYes
Check for airOperator visual inspection, confirmed by the user
Hand switchStart, stop and pause
Syringe heat maintainerYes, 95 degrees F plus or minus 9 degrees

Read as a list, those rows are the job description of the device. It delivers a set volume at a set rate, in several phases, so the contrast arrives as a compact bolus. It limits the pressure it will apply. It stores the protocols a department uses, so the same exam is injected the same way each time. And it stops when the technologist tells it to.

The published protocols show how the settings are used. The American Association of Physicists in Medicine’s adult multiphasic liver CT protocol (version 1.0, November 2025) calls for contrast injected at 3 milliliters per second or more, followed by a 30 to 40 milliliter saline chaser bolus. Preparing the injector matters as much as programming it: the ACR manual says standard procedures should be used to clear the syringe and pressure tubing of air, and that the injector and its tubing should be positioned to allow adequate table movement without tension on the IV line.

Injector Types

Single Head, Dual Head and Syringeless Injectors

Three kinds of CT contrast injectorThree kinds of CT contrast injectorWhat each design loads and what changes between patientsSingle headDual headSyringelessWhat is loadedOne syringe of contrastOne syringe of contrast andone of salineMultiple-use contrastcontainers and salineSaline on the sameinjectorNoYes, from the second syringeYes, saline for every patientBetween patientsFill a new syringeFill two new syringesChange the patient tubing onlyNamed by the sourcesSingle syringe packs, BraccoEmpowerCTA+, MEDRAD Stellant,OptiVantageGE HealthCare CT motionPer Applied Radiology (2020, sponsored by Bracco) and the makers' product pages. No design is recommended.
Figure 2. Single head, dual head and syringeless injectors compared. The difference is what the injector can load, which decides whether a saline flush is possible and how much work sits between patients.

CT injectors come in three designs, and the difference is what they can load. An article in Applied Radiology from August 2020, sponsored by the injector maker Bracco, summarizes the market: the use of single head injectors in CT has shifted significantly to dual head and syringeless injectors, whose advantage is that they permit loading of contrast and saline onto the same injector. It names Bracco’s EmpowerCTA+, Bayer’s MEDRAD Stellant and Guerbet’s OptiVantage among the dual head CT injectors available in the United States.

Single head. One syringe, filled with contrast. Bracco’s product page for the EmpowerCTA+ still lists a single syringe pack, one 200 mL syringe with an extension set and fill tube, alongside its dual syringe packs.

Dual head. Two syringes, one for contrast and one for saline, joined at the patient line. Bracco’s dual syringe pack includes Y tubing with one-way check valves. The second syringe is what makes a saline flush possible. According to the Applied Radiology article, which cites a 2010 review in the journal Radiology, a saline flush ensures complete delivery of the contrast dose into the circulation and can reduce the amount of iodine needed. The article describes a dual head protocol as a saline test injection to confirm the vein, then the power injection of the contrast bolus, then a saline chaser. Makers build features around the second syringe: Bracco’s page describes a function that runs saline from a switch at the patient’s side to test the vein before the procedure, another that moves straight to saline once opacification has been reached, and an accessory patch designed to help detect a possible extravasation and pause the procedure, which Bracco notes is not a substitute for patient monitoring.

Front view of a patient lying in the bore of a Siemens SOMATOM X.cite CT scanner with a dual-syringe contrast injector on an arm beside the gantry and coiled tubing running to the patient, photo courtesy of Siemens Healthineers
A dual head injector at the gantry: one syringe for contrast, one for saline, and coiled tubing with enough slack for the table to travel. Photo courtesy of Siemens Healthineers.

Syringeless. No syringes to fill. GE HealthCare’s page for the CT motion injector describes multiple-use contrast containers, an automatic tube feed set up once a day, and a workflow in which the technologist changes only the patient tubing and chooses the injection protocol between patients. The page lists automated air detectors, pressure sensors, one-way flow valves on the patient tubing and saline used for every patient, and says the unit can load two different types of iodinated contrast. GE cites a University of Washington study in which the syringeless injector saved 90 minutes a day in each CT suite compared with a dual syringe injector, and adds that the results are unique to that trial and may not be generalized.

For a buyer the choice is a workflow and consumables question more than an image quality one: how many contrast exams a day, how much CT angiography, who loads the injector, and what the department’s contrast contract looks like. None of the three designs is recommended here over the others.

The Patient’s Side

What Patients Report Feeling During the Injection

The patient sources agree closely. RadiologyInfo says that when an iodine-based contrast material is injected into the bloodstream, you may have a warm, flushed sensation and a metallic taste in your mouth that lasts for a few minutes. MedlinePlus says contrast given through an IV may cause a slight burning feeling, a metallic taste in the mouth and a warm flushing of the body, and that these sensations are normal and usually go away within a few seconds. RadiologyInfo adds that the needle may cause some discomfort when it is inserted and that there may be some bruising once it is removed.

Afterward, RadiologyInfo says, no recovery period is necessary if you have not been sedated: you may resume your usual activities and normal diet immediately, and increased fluid intake will help eliminate the contrast material from your body.

Two things are worth knowing about, because the imaging team watches for both.

A leak at the IV site. Occasionally contrast goes into the tissue around the vein instead of the vein, which is called extravasation. The ACR Manual on Contrast Media reports that 0.1 percent to 1.2 percent of CT injections result in extravasations, that most resolve without complication and that severe injuries are very rare. The manual says that if the patient reports pain or the sensation of swelling at the injection site, the injection should be discontinued, and RadiologyInfo tells patients to inform the nurse or technologist immediately if they feel pain or tingling there during or right after the injection.

A reaction to the contrast. The ACR manual puts allergic-like reactions to modern iodinated contrast at 0.6 percent in aggregate and 0.04 percent severe. RadiologyInfo lists nausea and vomiting, headache, itching, flushing and a mild skin rash or hives as mild reactions, says severe reactions are very uncommon and notes that radiology departments are well equipped to deal with them. MedlinePlus reminds patients that scanners come with an intercom, so the operator can hear them at all times, and tells them to speak up at once if they have any trouble breathing.

None of this replaces what your own imaging center tells you. Its staff know your history and the exam your doctor ordered.

Timing

Timing the Scan: The Phases After the Injection

Contrast does not sit still. It arrives in the arteries first, passes through the organs and returns through the veins, and the picture changes by the second. A contrast CT is therefore timed: the scan starts a set interval after the injection, chosen for what the radiologist needs to see. The liver is the textbook case because it has two blood supplies. A review of liver imaging guidelines in the Polish Journal of Radiology (2018) tabulates the phases after contrast injection as follows.

PhaseTime after contrast injectionWhat the liver looks like
Early arterial15 to 25 secondsThe portal vein is not yet enhanced
Late arterial30 to 40 secondsThe portal vein is enhanced; the hepatic veins are not yet
Portal venous70 to 80 secondsPortal veins and liver tissue are fully enhanced
Delayed2 to 5 minutesVeins and liver tissue enhance less than in the portal venous phase

Those windows are narrow, and people differ in how fast their blood circulates. For that reason the AAPM liver protocol recommends bolus tracking rather than fixed timing: as our contrast guide explains, the scanner watches a region of interest for the contrast to arrive and starts the scan when it does, not from the clock. The same protocol asks for the arterial phase at late arterial timing, which it also calls the hepatic arterial phase, and it requires a delayed phase. An exam that needs more than one of these phases is scanned more than once after a single injection, which is how a with and without or a multiphase study is built. Our article on the CT abdomen and pelvis with contrast follows one such exam from check-in to report, and the angiogram cost guide covers CT angiography, where the arteries themselves are the subject.

The times in the table are for the liver and come from one published review. Other organs and other questions use other delays, and each department writes its own protocols.

Screening

The Screening Questions a Center Asks First

Before a CT scan with IV contrast, the imaging center asks a short list of questions. They are the same questions everywhere because they come from the same guidance.

Have you reacted to contrast before? The ACR Manual on Contrast Media calls a prior allergic-like reaction to the same class of contrast the greatest risk factor for a future one, with roughly a fivefold increase in risk. MedlinePlus says people who have reacted before may need to take medicines before the test.

Do you have allergies? RadiologyInfo asks patients to tell their doctor about allergies to food, drugs, dyes, preservatives or animals. A common belief is addressed directly by the ACR manual: patients with shellfish or povidone-iodine allergies are at no greater risk from iodinated contrast than patients with other allergies.

How are your kidneys? RadiologyInfo lists a history of heart disease, diabetes, kidney disease or thyroid problems among the things to mention. The ACR manual suggests a kidney function test before contrast for patients with a personal history of kidney disease, including known chronic kidney disease, a past acute kidney injury, dialysis, kidney surgery or ablation, or albuminuria, with diabetes as an optional trigger, and says that patients without such risk factors do not require a baseline creatinine test before a routine study.

Do you take metformin? MedlinePlus says people taking this diabetes medicine may have to stop it for a while before the test. The ACR manual is more specific: with no acute kidney injury and an eGFR of 30 or above, it sees no need to stop metformin before or after intravenous iodinated contrast, and it advises withholding the drug for 48 hours after the procedure in patients with acute kidney injury or severe chronic kidney disease. That decision belongs to the patient’s own doctors.

Could you be pregnant, or are you breastfeeding? RadiologyInfo says women should always tell their physician or technologist if there is any possibility of pregnancy, and that iodinated contrast agents for CT are not known to pose any significant risk to the mother or baby. On breastfeeding, RadiologyInfo’s CT pages report that manufacturers advise a pause of 24 to 48 hours, and add that, according to the ACR manual, studies show the amount of contrast absorbed by the infant is extremely low.

Have you eaten? Instructions differ. MedlinePlus says you may be asked not to eat or drink for 4 to 6 hours before the test if contrast is used. The ACR manual states that fasting is not required before routine intravascular contrast administration, while acknowledging that some practices request it. Follow the instruction your own center gives you.

The Equipment Side

The Equipment Side: Why Scanner Speed Matters

Put the timing table next to the scanner and the buying question appears. If the early arterial phase of the liver lasts from 15 to 25 seconds after injection, the scanner has about ten seconds to cover the anatomy while the contrast is where the radiologist wants it. The FDA’s overview of CT says a single rotation of the X-ray source and detectors typically takes a second or less, and MedlinePlus notes that the newest scanners can image the entire body in less than 30 seconds. How much of the body one rotation covers depends on the detector, which is what slice count describes; our guide to CT scanner types by slice count explains what 16, 64 and 128 slices change in practice.

The Medical Outfitters CT scanner cost and price guide draws the line the same way. It describes the 16 to 32-slice class as the tier for routine head, chest, abdomen, spine and extremity CT at sites that do not need cardiac work, and the 64-slice class as the workhorse for hospitals and imaging centers because it adds coronary CT angiography and calcium scoring. The more a department’s contrast work leans toward the arteries, the more the faster tiers earn their place.

The injector is its own line in the plan. The same guide lists the contrast injector among the items quoted per project, next to the room’s lead shielding and electrical work, because it is chosen for the department and not shipped inside the gantry. A buyer planning a room that will offer contrast exams should settle these points before the quote is signed:

  • Injector type and mount. Single head, dual head or syringeless, on a floor stand or on an arm at the gantry or ceiling, with tubing long enough for the full table travel. The ACR manual asks that the injector and tubing allow table movement without tension on the IV line.
  • Bolus tracking and saved protocols. The AAPM recommends bolus tracking for multiphase liver work, so confirm that the scanner’s triggering software and multiphase protocols are licensed and transfer with a refurbished system. Our used CT scanner buying guide lists the licenses to check.
  • Contrast warming. Some injectors keep the syringe warm, as the FDA summary above shows. The ACR manual notes that warmed contrast is less viscous, does not recommend routine warming of lower-viscosity agents, and points out that The Joint Commission requires a daily temperature log and evidence of maintenance for any warmer.
  • Tube and generator. Repeated passes in a multiphase study load the X-ray tube; our article on how long a CT tube lasts explains how that wear is counted.
  • The room. Space at the table side for the injector and for the staff who place the line, and a clear view from the console. Our guide to CT scanner room size and requirements covers the dimensions.
Next Step

Planning a Contrast-Ready CT Room With Medical Outfitters

Medical Outfitters supplies new Fujifilm CT systems and MO Select refurbished scanners from GE, Siemens, Philips, Canon and Hitachi, delivered, installed and serviced across the United States, Puerto Rico and the Caribbean. If your CT service will run contrast exams, start with the CT scanner cost and price guide, which separates the scanner from the items quoted per project, then browse the CT scanners we list and the refurbished imaging equipment available through MO Select. For the scanner itself, see what a CT scan machine is and how it works and our comparison of CT scanner manufacturers; for keeping it running, our CT scanner service page. To talk through a room that will run contrast work from the first day, contact Medical Outfitters.

Sources

  • RadiologyInfo.org (RSNA and ACR), Contrast Materials, last reviewed August 25, 2024: what contrast is, what patients experience, side effects, pregnancy and breastfeeding. https://www.radiologyinfo.org/en/info/safety-contrast
  • RadiologyInfo.org, CT Angiography and Body CT, last reviewed June 15, 2026: the catheter in an arm vein, what to report at the IV site, breastfeeding. https://www.radiologyinfo.org/en/info/angioct and https://www.radiologyinfo.org/en/info/bodyct
  • MedlinePlus (National Library of Medicine), CT scan, review date July 15, 2024: the IV in the hand or forearm, sensations, fasting, metformin, the intercom, scan times. https://medlineplus.gov/ency/article/003330.htm
  • American College of Radiology, ACR Manual on Contrast Media, 2026: safe injection technique, catheter gauge and flow rates, extravasation and reaction rates, screening, kidney function, metformin, fasting, warming. https://edge.sitecorecloud.io/americancoldf5f-acrorgf92a-productioncb02-3650/media/ACR/Files/Clinical/Contrast-Manual/ACR-Manual-on-Contrast-Media.pdf
  • U.S. Food and Drug Administration, 510(k) summary K192370, MEDRAD Stellant FLEX CT Injection System, December 2019: device description, classification and specifications. https://www.accessdata.fda.gov/cdrh_docs/pdf19/K192370.pdf
  • U.S. Food and Drug Administration, Computed Tomography (CT), content current as of May 1, 2023: rotation time. https://www.fda.gov/radiation-emitting-products/medical-x-ray-imaging/computed-tomography-ct
  • National Institute of Biomedical Imaging and Bioengineering, Computed Tomography (CT): why contrast agents are used. https://www.nibib.nih.gov/science-education/science-topics/computed-tomography-ct
  • American Association of Physicists in Medicine, Adult Multiphasic Liver CT Protocols, version 1.0, November 10, 2025: injection rate, saline chaser, bolus tracking. https://www.aapm.org/pubs/CTProtocols/documents/Adult_Tri-phasic_Liver_HCC_AAPM_format_Clean.pdf
  • Polish Journal of Radiology, CT/MRI LI-RADS v2017: review of the guidelines, 2018;83:e355: liver phases after contrast injection. https://pmc.ncbi.nlm.nih.gov/articles/PMC6323546/
  • Applied Radiology, The Benefits of Saline and Dual-Head Injectors, August 6, 2020 (sponsored by Bracco): injector types and the saline flush. https://appliedradiology.com/articles/the-benefits-of-saline-and-dual-head-injectors
  • Bracco, EmpowerCTA+ Injector System product page, and GE HealthCare, CT motion injector product page: maker descriptions of dual syringe and syringeless designs. https://www.bracco.com/en-ca/product/empowercta and https://www.gehealthcare.com/en-us/products/contrast-media/ct-motion
Frequently Asked Questions

IV Contrast for CT: Common Questions

What is IV contrast for CT?

IV contrast for CT is an iodine-based liquid injected into a vein, usually in the arm, before or during a CT scan. RadiologyInfo explains that iodine blocks or limits the X-rays passing through, so the blood vessels and organs that temporarily hold the contrast look different on the images. It is not a permanent dye, and the body eliminates it afterward. A power injector normally delivers it at a set rate.

How is IV contrast given for a CT scan?

Through an IV line. MedlinePlus says the contrast may be delivered through a vein in the hand or forearm. The ACR Manual on Contrast Media says it should be given by power injector through a flexible plastic cannula, with an elbow or large forearm vein preferred, and that the line can be checked with a saline test flush first. A radiologist, technologist or nurse may give it, subject to state law.

What does IV contrast feel like?

RadiologyInfo says you may have a warm, flushed sensation and a metallic taste in your mouth that lasts for a few minutes. MedlinePlus describes a slight burning feeling, a metallic taste and a warm flushing of the body, and says these sensations are normal and usually go away within a few seconds. Tell the technologist at once about pain or swelling at the IV site or any trouble breathing.

What is a CT power injector?

A power injector is a machine that pushes contrast through the IV line at a volume and flow rate the technologist programs. The FDA regulates it as a Class II device. One FDA 510(k) summary, for the Bayer MEDRAD Stellant FLEX, lists a flow rate range of 0.1 to 10 mL per second, a programmable pressure limit from 50 to 325 psi, and memory for 250 protocols of up to six phases each.

What is the difference between a single head and a dual head injector?

A single head injector holds one syringe of contrast. A dual head injector holds two, one of contrast and one of saline, so it can flush the line with saline after the contrast. Applied Radiology, in an article sponsored by Bracco, reports that CT has shifted from single head injectors to dual head and syringeless ones, and that a saline flush ensures complete delivery of the contrast dose.

How long after the injection is the CT scan taken?

It depends on what the radiologist needs to see. For the liver, a 2018 review in the Polish Journal of Radiology places the early arterial phase at 15 to 25 seconds after injection, the late arterial phase at 30 to 40 seconds, the portal venous phase at 70 to 80 seconds and the delayed phase at 2 to 5 minutes. The AAPM recommends bolus tracking over fixed timing for multiphase liver scans.

Do I need a kidney test or to fast before IV contrast?

Ask your imaging center, because instructions differ. The ACR Manual on Contrast Media suggests a kidney function test for patients with a history of kidney disease, with diabetes as an optional trigger, and says patients without those risk factors do not need one before a routine study. It also states that fasting is not required before routine contrast, while MedlinePlus says you may be asked not to eat or drink for 4 to 6 hours.

Does the CT scanner need to be fast for contrast exams?

Yes, for exams timed to the arteries. If an early arterial phase lasts about ten seconds, the scanner must cover the anatomy inside that window. The Medical Outfitters CT scanner cost guide describes 16 to 32-slice systems as the tier for routine CT and 64-slice systems as the workhorse that adds coronary CT angiography, and it lists the contrast injector among the items quoted per project.